Home / Products

Products

0
  • HV Capacitor Compensation Complete Set

    1.Rated voltage: 6–10kV.
    2.Frequency: 50Hz.
    3.Capacity: 100–10,000kVar.
    4.Ambient temperature: -25℃ ~+45℃;
    5.Reactor options:.
    Inrush suppression: 0.1–1% reactance.
    5th+ harmonic suppression: 6% reactance.
    3rd+ harmonic suppression: 12% reactance.

  • Air Core Current Limiting Reactor

    XKGKL series dry-type air-core current limiting reactor in series connection in system line, increase the system impedance,the system failure limit short circuit current, the fault current dropped to permissible value.

  • Y10W-102/266W Lightning Arrester Porcelain housed MOA for AC system

    1.Rated Voltage:102kV
    2.unit number:1
    3.DC reference voltage:≥148kV
    4.Creepage Distance:25/31
    5.The lightning arrester has superior protective performance,reliable sealing performance,satisfactory ageing performance,safe pressure relirf capability and uninterrupted innovation in Hi-tech product development.

  • 35kV Oil-immersed Power/Distribution Transformer

    1.Input voltage:35kV,Output voltage:10.5/6.3/3.15kV
    2.Frequency:50/60Hz
    3.Capacity:800~31500kva
    4.Rated voltage:35kV
    5.Winding material:copper\Aluminum
    6.Taping range of HV:±5%
    7. Features S9 (off-circuit tap changer) and SZ9 (on-load tap changer) models.

  • LW25 Outdoor Porcelain Type SF6 Circuit Breaker

    1.Rated Voltage:126/145kV
    2.Rated frequency:50Hz
    3.Rated Normal Current:2000,3150,4000A
    4. Spring: Electric motor charges closing spring; self-charges opening spring during closure.
    5.Hydraulic: Disc spring energy storage (no nitrogen) with hydraulic actuation.
    6.Pneumatic: Compressed-air opening / spring closing.

  • GW4 High Voltage Disconnect Switch

    1.Hot-dip galvanized steel components
    2.Stainless steel transmission system (pins, bushings, joints, bearings)
    3.Flexible busbar connections
    4.Externally compressed stainless contact springs (anti-rust, stable pressure)
    5.Aluminum alloy profile
    6.Enhanced heat dissipation, maintenance-free
    7.Bent copper plates (easy maintenance)
    8.Short friction travel during operation
    9.Grading rings + shields at contacts
    10.Optimized E-field distribution, reduced RF interference
    11.Optional installation on both base sides
    12.rated voltage:40.5-252kv
    13.rated current:max 6300A

  • KYN61-40.5 Removable Metal-Clad Switchgear

    1.Rated Voltage:40.5kV 2.Rated Current:630,1250,1600,2000,2500A 3.Altitude:≤2000m 4.Ambient temperature: -10°C ~ +40°C

  • 10KV High voltage Shunt High-Voltage Capacitors

    1.Rated Voltage:6kV,10kV,35kV
    2.Rated Capacity:1-100Mvar(per bank)
    3.The capacitor is mainly consisted of container and device body.
    4.The core is consisted of severalelements and insulation parts. The element is rolled, pressed andmade of two aluminum foilsand somepiece of thin dielectric polypropylene films sandwiched betweenthe two aluminum foils. In order to reach the differentdemand of voltage and capacity, the elements in core is connected by someseriesand parallelmethod. The technology of aluminum foiledge folding and protruding weldingare used to reduce the loss and increase the performance of partial discharging.

  • capacitor bank for 3 phase motor

    1. Automatic compensation load reactive power, improve the load power factor;
    2. Reduce network loss, high efficiency and energy saving;
    3. Control harmonics of the system or control harmonics according to user requirements;
    4. Reduce reactive current, save transformer capacity cost, improve transformer output.
    5. Voltage priority control, the voltage regulation function of the capacitor can be used to improve the voltage pass rate.

  • capacitor bank in electrical panel

    1. Automatic compensation load reactive power, improve the load power factor;
    2. Reduce network loss, high efficiency and energy saving;
    3. Control harmonics of the system or control harmonics according to user requirements;
    4. Reduce reactive current, save transformer capacity cost, improve transformer output.
    5. Voltage priority control, the voltage regulation function of the capacitor can be used to improve the voltage pass rate.

  • capacitor bank in distribution system

    1. Automatic compensation load reactive power, improve the load power factor;
    2. Reduce network loss, high efficiency and energy saving;
    3. Control harmonics of the system or control harmonics according to user requirements;
    4. Reduce reactive current, save transformer capacity cost, improve transformer output.
    5. Voltage priority control, the voltage regulation function of the capacitor can be used to improve the voltage pass rate.

  • capacitor bank in 33/11kv substation

    1. Automatic compensation load reactive power, improve the load power factor;
    2. Reduce network loss, high efficiency and energy saving;
    3. Control harmonics of the system or control harmonics according to user requirements;
    4. Reduce reactive current, save transformer capacity cost, improve transformer output.
    5. Voltage priority control, the voltage regulation function of the capacitor can be used to improve the voltage pass rate.